Electric rotary multi-turn actuator with three-phase electric motor, version Control. Design for surrounding temperature from -40°C to +60°C. Protective enclosure IP55. Tripping torque: 20 to 200Nm, flange size F10 according to ISO 5210.
Current configuration type number:
8 | Mechanical connection: Shape D according to DIN 3210. Electric connection: Bushings. |
7 | Design without transmitter, with local control unit for version Control. |
2 | Tripping torque: 20 to 40Nm, position-changing velocity: 25 1/min. |
E | Design with brake and contactor combination, without signalling, without position transmitter and blinker. |
G | Design with brake and contactor combination, with signalling switches. |
I | Design with brake and contactor combination, with blinker. |
K | Design with brake and contactor combination, with signalling switches and blinker. |
M | Design with contactor combination, without signalling, without position transmitter and blinker. |
Q | Design with contactor combination and signalling switches. |
R | Design with contactor combination and blinker. |
T | Design with contactor combination, with signalling switches and blinker. |