Electric linear thrust actuator with electronic control system. Design for surrounding temperature from -40°C to +60°C. Protective enclosure IP55. Range of tripping force setting: 11,5 to 25kN.
Current configuration type number:
K | Electronic system DMS2ED – with contactors and brake. Electric connection: Connector. |
M | Pitch of pillars: 150mm, position Closed: 74mm. Pillars version: threaded flange, thread in clutch: M16x1,5. |
6 | Tripping force: 15 to 25kN. Position-changing velocity: 125mm/min. |
N | Electronic system DMS2ED - local control, contactors or contact-less control, analog module - transmitter, position controller. |
NED | Type number supplement. |