Configurator of Actuators ZPA Pečky, a.s.

MTN 52443

Electric linear thrust actuator, protective enclosure IP55. Range of tripping force setting: 25 to 63kN.

Current configuration type number:

Additional positions for type number combination:

7Electric connection: Connector.

1Design with pillars.

2Tripping force: 25 to 40kN. Position-changing velocity: 125mm/min.

0Design with current transmitter 4-20mA.
1Design with current transmitter 4-20mA and with local control unit.
2Design with resistance position transmitter 2x100 Ohms.
3Design with resistance position transmitter 2x100 Ohms and with local control unit.
4Design with resistance position transmitter 2x100 Ohms, contactor combination, without local control, without brake and position controller.
5Design with resistance position transmitter 2x100 Ohms, contactor combination, without local control, with brake, without position controller.
6Design without position transmitter, without local control unit, with contactor combination, with brake, without position controller.
7Design with resistance position transmitter 2x100 Ohms, contactor combination, with local control, without brake and position controller.
8Design with resistance position transmitter 2x100 Ohms, contactor combination, with local control, with brake, without position controller.
9Design without position transmitter, with contactor combination, without local control unit, without brake and position controller.
ADesign with current transmitter 4-20mA, contactor combination, without local control, without brake and position controller.
BDesign with current transmitter 4-20mA, contactor combination, without local control, with brake, without position controller.
CDesign with current transmitter 4-20mA, contactor combination, without local control, with brake and position controller.
DDesign with current transmitter 4-20mA, contactor combination, with local control, without brake and position controller.
EDesign with current transmitter 4-20mA, contactor combination, with local control, with brake, without position controller.
FDesign with current transmitter 4-20mA, contactor combination, with local control, with brake and position controller.
HDesign without position transmitter, with local control unit and contactor combination, without brake and position controller.
KDesign with current transmitter 4-20mA with power supply, contactor combination, without local control, without brake and position controller.
LDesign with current transmitter 4-20mA with power supply, contactor combination, without local control, with brake, without position controller.
MDesign with current transmitter 4-20mA with power supply, contactor combination, with local control, without brake and position controller.
NDesign with current transmitter 4-20mA with power supply, contactor combination, with local control, with brake, without position controller.
PDesign without position transmitter, with local control unit.
RDesign with current transmitter 4-20mA and power supply unit, without local control unit.
SDesign with current transmitter 4-20mA, with built-in power supply, with local control unit.
UDesign without position transmitter, with local control unit, with brake and contactor combination, without position controller.
ZDesign without position transmitter, without local control unit.