Configurator of Actuators ZPA Pečky, a.s.

MTN -40°C 52442

Electric linear thrust actuator. Design for surrounding temperature from -40°C to +60°C. Protective enclosure IP55. Range of tripping force setting: 11,5 to 25kN.

Current configuration type number:

Additional positions for type number combination:

6Electric connection: Terminal board.

JPitch of pillars: 150mm, position Closed: 74mm. Pillars version: with nut, thread in clutch: M16x1,5.

0Tripping force: 11,5 to 15kN. Position-changing velocity: 50mm/min.

0Design with current transmitter 4-20mA.
1Design with current transmitter 4-20mA and with local control unit.
2
3
4
5
6Design without position transmitter, without local control unit, with contactor combination, with brake, without position controller.
7
8
9Design without position transmitter, without local control unit, with contactor combination, without brake and position controller.
ADesign with current transmitter 4-20mA, contactor combination, without local control, without brake and position controller.
BDesign with current transmitter 4-20mA, contactor combination, without local control, with brake, without position controller.
CDesign with current transmitter 4-20mA, contactor combination, without local control, with brake and position controller.
DDesign with current transmitter 4-20mA, contactor combination, with local control, without brake and position controller.
EDesign with current transmitter 4-20mA, contactor combination, with local control, with brake, without position controller.
FDesign with current transmitter 4-20mA, contactor combination, with local control, with brake and position controller.
HDesign without position transmitter, with local control unit and contactor combination, without brake and position controller.
KDesign with current transmitter 4-20mA with power supply, contactor combination, without local control, without brake and position controller.
LDesign with current transmitter 4-20mA with power supply, contactor combination, without local control, with brake, without position controller.
MDesign with current transmitter 4-20mA with power supply, contactor combination, with local control, without brake and position controller.
NDesign with current transmitter 4-20mA with power supply, contactor combination, with local control, with brake, without position controller.
PDesign without position transmitter, with local control unit.
RDesign with current transmitter 4-20mA and power supply unit, without local control unit.
SDesign with current transmitter 4-20mA, with built-in power supply, with local control unit.
UDesign without position transmitter, with local control unit, with brake and contactor combination, without position controller.
ZDesign without position transmitter, without local control unit.